Negotiable, Depends on size, Depends on specification
FOB
Depend on quantity
Accuracy | ±0.5% of Rate (Option : ±0.2 %) | |
Repeatability/Reproducibility | 0.05% / ±0.25% (Option : ±0.2 %) | |
Measurement range | 0.1 ~ 10 m/s (Option : 0.1m/s or less can be measured) Turn down ratio - 20:1 |
|
High stability | 1) Square Wave excitation drive method 2) Noise removal 3) Realization of high zero stability |
|
Fluid conductivity | More than 5μS/cm | |
Communication, output | 1) RS-485(Modbus) 2) HART Communication(Option) 3) TMS Communication(Option) 4) USB Memory Storage(Option) |
|
Function | 1) Self-diagnosis function 2) Easy output calibration function 3) Real-time status display (instantaneous flow, totalized flow, flow rate, error message, alarm) 4) Flow simulation function 5) Pulse adjustment (semi-automatic) |
|
Temperature effect | Transmitter | < ±0.03% / 10℃ (50℉) |
Analog output | < ±0.1% / 10℃ (50℉) | |
Sensor | < ±0.03% / 10℃ (50℉) | |
Operating Temperature (Ambient) | 25℃ ~ 60℃ (-13℉ ~ 140℉) | |
Warranty Period | 1year |
Operating Temperature (Fluid Temperature) | PTFE Lining | -10℃ ~ 150℃ (14℉ ~ 302℉) |
Rubber lining | -10℃ ~ 80℃ (14℉ ~ 176℉) | |
Operating pressure range | 15A ~ 80A | 40.0 kg/cm2 |
100A ~ 150A | 20.0 kg/cm2 | |
200A ~ 900A | 10.0 kg/cm2 | |
1000A ~ | 5.0 kg/cm2 | |
Sensor Material | Carbon Steel, STS304 | |
Lining material | PTFE, PFA, Hard Rubber | |
Electrode material | STS316L, Titanium, Hastelloy-C, Hastelloy-B, Tantalum, Platinum | |
flange | JIS 10K, JIS 20K, ANSI, DIN, KS (etc.) | |
Sensor installation environment | Protection grade | IP65 (Option: Integral, IP67) |
Cable entry standard | M20✕1.5 Cable Grand (Std.) |
LCD Display | 1) Graphic LCD 2) Instantaneous Flow 3) Forward flow rate 4) Reverse totalized flow display 5) Alarm display with flow rate text and digital signal 6) Option : Clock display |
|
Internal integrated circuit | Built-in 15 bit digital integrated circuit V/F Converter | |
Program | 1) Standard Type 2) Option : HART Type, USB Type (separated only) |
|
Power supply | AC 85~230V, 50~60Hz, Max. Power 15W | |
Output Output | Analog output | 4-20mA (Load resistance ≤ 500Ω) |
Analog output resolution | < 0.02mA | |
HART communication(Option) | AMS, HHT375/475 interworking, SIEMENS PDM interworking | |
Pulse output | Parameters such as pulse width can be modified - When selecting frequency : Frequency range 1~3,000Hz can be set between - When selecting pulse: 0~1000Hz square wave pulse signal setting |
|
Alarm Alarm | - High, High-High Alarm Alarm: % can be set, alarm output or not can be set - Low, Low-Low Alarm Alarm: % can be set, alarm output or not can be set |
|
Operating Temperature (Ambient Temperature) | 25℃ ~ 60℃ (-13℉ ~ 140℉) | |
Internal Protection Rating | IP65 (Option : Integral, IP67) | |
Settings | Setting contents are saved for 10 years, and the setting value can be changed if necessary. | |
Self-diagnosis | Transmitter can check whether the sensor is healthy or not (Sys Error, Mtp Error) | |
Cable entry standard | M20✕1.5 Cable Grand (Std.) | |
Transmitter Material | Aluminum |
The person in charge
Sangsoo KimAddress
14 Dunchon-daero 457beon-gil Jungwon-gu, Seongnam-si, Gyeonggi-do (13218)⠀⠀
Please enter the text on the left image to prevent automatic input.